Chemical agents filtration at high temperatures [L008]

L008 - Chemical agents filtration at high temperatures
  • Machine type Rinser
  • O&U Themes Cost optimisation
  • Complexity3/3
  • Machine Sub-assemblyRinser

Description

10-60 micron filtration at temperatures between 60°C and 85°C Purpose To filter liquid from 10 to 60 microns at a temperature varying between 60°C and 85°C Components 1) Containers with seals adapted for temperature resistance 2) Filter cartridges from 10-60 micron in temperature-resistant material Process logic Filtration of liquids with temperatures of 60°C to 85°C with filtration between 10 and 60 micron. N.B. Maximum liquid temperature 85°C. Size and the cost of the illustrated system depends on the throughput of liquid.


Key message
Avoid the pollution of rinsing solution

Machine application

Rinser SIMONAZZI LGH


Benefits

Improved purity of rinsing liquid