Beschreibung
When the machine is stopped and de-energized, the blow nozzle cylinder may slowly go down due by its own weight and lack of seal friction.
The mobile part, attracted by magnets, remains in upper position.
The magnetic part is set with the screws of the blow nozzle cylinder.
The cylinder rod is hold in up position by two half-flanges, clamped on it, attracted by magnets.
Includes a U shape tool to adjust the air gap.
Schlüssel Meldung
Maschinen Anwendung
Blower Series2
Nutzen
Ease maintenance operations: avoid blow nozzle cylinder self dropping, and so, avoid interference / damage with transfer grippers.
Easy to install
Can be installed on all or only some of the stations without drilling.
No electrical modification.
No lubrification required.